Signal-10 Programming
3 Short Failure The external load circuit connected to the output is monitored for short
circuit failures
4 Open and Short Failure The external load circuit connected to the output is monitored for open
and short circuit failures
By default, for relay outputs 3 and 4 the maximum level of trouble monitoring is set (the Monitor For
parameter is set to 4).
Relay ON/OFF Events
The Relay ON/OFF Events parameter can be set on individually for each relay output. If the parame-
ter is set on then alterations of output conditions are transmitted to a network controller. By default
this parameter is set off.
When all settings are completed, don’t remember to save them by loading to the device memory (us-
ing the
toolbar icon or Device
Write Configuration to This Device menu command).
81 www.bolid.com